Subcategory:
A linear axis can move smoothly and count displacement correctly after start-up while still using a shifted machine coordinate. We check the recovery of the origin separately from the quality of motion and the accuracy of subsequent positions. For an axis that uses incremental feedback, the start-up procedure is part of the measuring system.
Trace the steps that establish a coordinate
For many incremental encoders, the scale and readhead provide the feedback the controller uses to track movement. A reference mark can provide a repeatable event when the readhead passes it. A home switch may guide the control to the right part of the travel, depending on the design. The controller then applies its configured rules and offsets to establish a machine coordinate. Document each step before changing settings or replacing parts.
The coordinate is particularly important when a measurement programme moves to stored positions. A shifted origin can cause a search window to miss an edge or inspect a neighbouring feature. Some routines can align a part independently from the machine origin, but they still depend on the stage reaching a location from which the alignment features can be found.
Verify the position against a fixed reference
We choose an independent reference the system can observe safely, such as a mounted artifact or an approved setup target. After homing, we record its indicated position under a consistent measurement setup. Measuring repeatedly without powering down establishes the short-term baseline. Starting again from a safe location and repeating the approved homing routine tests a different question: whether coordinate recovery returns the axis to the same frame.
Log the start location, approach direction, whether the reference event was detected and the position reported on the verification target. Record the control and programme revisions as well. If the control only supports one homing direction, follow the documented sequence and vary only the supported starting positions. Do not change protective limits or bypass the machine's normal start-up checks to widen the trial.
Use the result to narrow the investigation
If all verified positions shift by a similar amount after a restart, review the reference event and controller offset first. If the reported positions diverge as travel increases, compare results at more than one location and review the scale, the mapping and the measurement setup. These patterns provide leads. A fixed observation alone cannot tell us whether the underlying cause is a switch, an offset, a loose artifact or another contributor.
If the reference search sometimes fails, preserve the symptoms before repeating the procedure. Note the starting position and whether the axis recognised the intended mark. For exposed linear encoders, review its accessible mounting and cleanliness using the model's instructions. If a readhead or cable has changed, confirm that the combination supports the expected feedback and reference signal before assessing repeatability.
Check the first inspection move as well
A standalone position check can pass while a programme still moves incorrectly after recovery. Some routines retain a work offset or restore an earlier setup automatically. We have the operator identify the first stored feature and verify whether the restored settings match the part that is actually loaded. If the job uses alignment targets, two repeats of their measured positions can show whether the origin check and the programme check agree.
For a suitable shaft inspection on a Horizontal Instant Vision Measuring Machine, the demonstration can include opening the intended job and confirming that the first silhouette feature is inside its search window. On other Video Measuring Systems, the corresponding check might be a fiducial on a fixture. The embedded video illustrates optical shaft inspection. It does not demonstrate the encoder homing procedure discussed here.
When comparing candidate linear scales for a machine rebuild, we ask the system designer to identify the actual reference output and the control setting used to capture it. The controller may require a specific edge or polarity. An electrical indication that looks normal during motion should be assessed separately from the availability and stability of the reference event. If the design uses multiple marks, the controlled search segment or reference configuration needs to make the intended mark identifiable on every supported start.
Define recovery as part of acceptance
We recommend agreeing the allowable variation of the verification target and how many restarts the acceptance trial should cover. Test conditions should reflect the way the machine is used. A brief shutdown and a start after a weekend may produce different environmental conditions. An axis that is safe to resume and a process that is ready to release parts can also have different checks.
A useful report preserves the first verification result after start-up and any later checks. If a correction is made, record the previous result, the change and who verified the new state. If the position is outside the agreed limit, record the exception and follow the site's procedure before resuming measurements that depend on it.
For an application review, send the encoder model, controller reference procedure, travel and verification results to handing3d@163.com. We can help identify the information needed to check the specified feedback configuration or select suitable optical linear encoders.
Han Ding offers a one-stop service from needs analysis, product solutions, usage guidance, to after-sales tracking
Address:No. 98, Zhen'an East Road, Chang'an Town, Dongguan City, Guangdong Province, China
Mobile:+86-130 3887 8595 / Aico Ding